Warning We use cookies to improve your experience on our site. Cookies enable you to enjoy certain features (like saving your bag), social sharing functionality (for Facebook, Instagram, etc.) and to tailor messages and display ads to your interests (on our site, and others). They also help us understand how our site is being used. By continuing to use our site you consent to use our cookies. I agree

EPS Roof & Floor GOLD

13,65 kr / m² inc. VAT, excl. shipping
(10,93 kr excl. VAT and shipping)
EPS-DIP-GOL-020
+

Minimum quantity for "EPS Roof & Floor GOLD" is 1.

Add to wish list

High-performance HOT DOTTED expanded polystyrene, recommended for insulating roofs, ceilings and floors. GOLD roof/floor EPS carries average mechanical loads which do not exceed 3.0 t/m2.

Application

  • ground floors in residential, public and industrial buildings with small loads
  • floors with underfloor heating systems
  • floors on all kinds of rigid ceiling structures
  • floors of public buildings
  • flat roofs
  • external ceilings
  • light structure roofs (trapezoid metal sheet roofs)
  • verandas, balconies

Instructions

EPS boards should be applied in accordance with the best building practice and the guidelines contained in the construction design. The basic guidelines for laying the thermal insulation of floors and ceilings are as follows: make sure that the screed is flat and dry, otherwise level it out. The floors on the ground require a moisture barrier (in the form of tar paper, PE film, bituminous, water-based sealants). In ceilings between floors, apply a separating layer of PE film. Where the floor meets the wall, use an expansion jointing tape. Start laying the boards in the corner and place the first row of boards from the wall by pushing them against the expansion jointing tape. Subsequent rows should be laid in offset configuration, avoiding the crossing of board joints. When all insulation is in place (can be in two or more layers), spread a PE film with a minimum of 0.2 mm in thickness, to protect the board joints from moisture and penetration of the screed into the spaces between the EPS boards. Where water-based floor heating is used, install the heating cables with suitable clips on the boards on which the PE film is already spread. Please note that the thickness of the screed needs to be increased by the outer diameter of the floor heating cables.

Packaging, storage, transport

GOLD roof/floor boards are supplied in the original manufacturer's packaging only. The label on the packaging contains the following information: product name, manufacturer's name and factory name, production date, Standard EN 13163 number, code according to this standard, declared technical characteristics. GOLD roof/floor boards should be stored in a manner to protect them against damage and weather conditions.

Thermal resistance of the EPS for ROOFS & FLOORS

Thickness Thermo
Plus
Thermo Gold Silver Standard
mm m2K/W
10 0.30 0.25 0.25 0.25
20 0.60 0.55 0.50 0.50
30 0.90 0.80 0.80 0.75
40 1.25 1.10 1.05 1.00
50 1.60 1.35 1.35 1.25
60 1.90 1.65 1.60 1.50
70 2.25 1.90 1.85 1.75
80 2.55 2.20 2.15 2.00
90 2.90 2.50 2.40 2.25
100 3.20 2.75 2.70 2.50
110 3.50 3.05 2.95 2.75
120 3.85 3.30 3.20 3.00
130 4.15 3.60 3.50 3.25
140 4.50 3.85 3.75 3.50
150 4.80 4.15 4.05 3.75
160 5.15 4.40 4.30 4.00
170 5.45 4.70 4.55 4.25
180 5.80 5.00 4.85 4.50
190 6.10 5.25 5.10 4.75
200 6.45 5.50 5.40 5.00
Thermal conductivity:
0.036
Compressive stress by 10% relative deformation:
100 kPa
Fire resistance:
Euroclass E

Dimensions

Width:
500mm
Length:
1000mm

No posts found