10713 |
en |
2 |
Flashing for VELUX roof windows |
|
|
<p style="text-align: justify;">Flashings are essential for insulating the connection between the roof window and the roof. Only by using a flashing will water running off the roof surface be transported sideways around the roof window, preventing water, dust or snow from entering the roof. A flashing must be purchased separately for most of roof windows. Because roofing materials can very different, Velux tries to offer the right product for every roofing material.</p>
<p style="text-align: justify;">Flashing and window's profile are made as standard of requiring no maintenance aluminum sheet in Grey (RAL 7043).</p>
<h2 style="text-align: justify;">Flashing for flat and profiled roofing materials</h2>
<p style="text-align: justify;"><strong>EDZ</strong></p>
<ul>
<li>Flashing for installing VELUX roof windows into flat and profiled roofing materials with thickness from 15 - 45mm in profile (from 4.5 cm height, select EDW).</li>
<li>Suitable for roofing materials such as: Interlocking pantiles, flat roofing tiles, flat cremains, reform pantiles, Frankfurt pantiles, Taunus pantiles, flat tiles, Heidelberg pantiles, plain tiles in crown roofing.</li>
<li>Suitable for roof pitches 20 - 90 degrees.</li>
</ul>
<p><strong>EDW</strong></p>
<ul>
<li>Flashing for installing VELUX roof windows into flat and profiled roofing materials with thickness from 15-120mm in profile.</li>
<li>Suitable for roofing materials such as: monastery tile, monastery tile, monk and nun, Florento tile, Mistral tile, Toledo tile as well as thatch, straw, corrugated sheets 5-, 6-, 8-wave, Berlin wave.</li>
<li>Suitable for roof pitches 15 - 90 degrees.</li>
</ul>
<p><strong>EDT</strong></p>
<ul>
<li>Flashing for installing VELUX roof windows into flat interlocking tiles with a max thickness from 15-40 mm.</li>
<li>Suitable for flat tiles such as: Koramic Wienerberger Orea 9, Monier Braas Turmalin, Braas Teviva, Braas Reviva, Creaton Domino, Nelskamp Nibra, Wienerberger Koramic Acuta, Erlus Linea and many more.</li>
<li>For roof pitches: 20°-90</li>
</ul>
<p><strong>EDJ </strong></p>
<ul>
<li>Flashing for installing VELUX roof windows into flat interlocking tiles and profiled roofing material with thickness from 15-90 mm</li>
<li>Suitable for roof tiles and concrete roof tiles such as: Interlocking tiles, flat roof tiles, flat cremone, reform tile, Frankfurt tile, flat tile, Heidelberg tile, corrugated sheets 5-, 6-, 8-wave, Berlin wave, plain tile in crown and double covering.</li>
<li>Suitable for roof pitches 20 - 90 degrees.</li>
</ul>
<h2>Flashing frame for flat roofing materials</h2>
<p><strong>EDS</strong></p>
<ul>
<li>Flashing for installing VELUX roof windows into flat roofing materials up to 16mm high (2 x 8mm). Side panels with continuous standing rabbets.</li>
<li>Suitable for: Slate (e.g. German and old German roofing), wooden shingles, roof tiles.</li>
<li>Suitable for roof pitches 15 - 90 degrees.</li>
</ul>
<p><strong>EDL</strong></p>
<ul>
<li>Flashing for installing VELUX roof windows into flat roofing materials up to 16mmm high (2 x 8mm). Side parts as layered pieces without standing rabbets.</li>
<li>Suitable for: Slate (e.g. rectangular template double roofing), wood shingles, roofing felt, roofing sheets, bitumen shingles, bitumen sheeting.</li>
<li>Suitable for roof pitches 15 - 90 degrees.</li>
</ul>
<p><strong>EDN</strong></p>
<ul>
<li>Flashing for installing VELUX roof windows into flat flashing materials up to 16mm high (2 x 8mm).</li>
<li>Suitable for: Slate (e.g. rectangular template double roofing), wood shingles, roofing felt, roofing sheets, bitumen shingles, bitumen membranes.</li>
<li>Suitable for roof pitches 20 - 90 degrees.</li>
</ul>
<p><strong>EDB</strong></p>
<ul>
<li>Flashing for installing VELUX roof windows into flat flashing materials up to 38mm high (2 x 19mm)</li>
<li>Suitable for: Plain tile in double covering.</li>
<li>Suitable for roof pitches 25 - 90 degrees</li>
</ul>
<p><strong>EDP</strong></p>
<ul>
<li>Flashing for installing VELUX roof windows into flat roof tiles without interlocking, with double overlap Maximum thickness: 28 mm (2 x 14mm)</li>
<li>Maximum length of tiles: 300 mm</li>
<li>Suitable for roof pitches 20-90 degrees.</li>
</ul>
<p><strong>EDQ</strong></p>
<ul>
<li>Unique mounting solution for roofing in standing seam</li>
<li>Allows mounting with a wide range of standing seam roofing of seam heights 25-40mm</li>
<li>Suitable for roof pitches 15-90 degrees</li>
</ul>
<h2>Additional procuts</h2>
<p><strong>Underfelt collar BFX 1000</strong></p>
<p>The foil flashing serves as a reliable seal between the roof window and the sub-roof. The adjustable rain gutter directs water flowing down from above away from the roof window.</p>
<p><strong>Insulation collar BDX 2000</strong></p>
<p>In addition to the BFX 1000 connection collar (foil connection and water drainage gutter), includes an insulation frame made of flexible foam for a tight and secure fit on the roof structure.</p>
<p><strong>Vapour Barrier BBX</strong></p>
<p>The vapor barrier apron provides an airtight and vapor-tight connection to the roof-side airtight layer and vapor barrier (including adhesive tape). Foil collar matched to the window size with welded corners and clamping profiles.</p>
|
|
|
|
|
|
|
|
N |