SELECT 
  cscart_product_descriptions.product_id, 
  cscart_product_descriptions.short_description, 
  IF(
    cscart_product_descriptions.short_description = '', 
    cscart_product_descriptions.full_description, 
    ''
  ) AS full_description, 
  cscart_product_descriptions.meta_keywords, 
  cscart_product_descriptions.meta_description, 
  cscart_product_descriptions.search_words, 
  cscart_product_descriptions.promo_text 
FROM 
  cscart_product_descriptions 
WHERE 
  cscart_product_descriptions.product_id IN (10105, 10107, 10162, 10106) 
  AND cscart_product_descriptions.lang_code = 'se'

Query time 0.00038

Explain
id select_type table type possible_keys key key_len ref rows Extra
1 SIMPLE cscart_product_descriptions range PRIMARY,product_id PRIMARY 9 4 Using index condition

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text
10105 <p style="text-align: justify;"><strong>Polyisocyanurate panels</strong> are used as a component of thermal insulation systems. They provide efficient thermal insulation as compared to other construction materials such as mineral wool or foamed polystyrene. They allow for cost-effective, long-lasting, and safe use of a house or an apartment.</p><p style="text-align: justify;"><strong>Polyisocyanurate panels </strong>are used to insulate:</p><ul style="text-align: justify;"><li>foundations;</li><li>walls;</li><li>exterior walls;</li><li>ceilings;</li><li>terraces and balconies;</li><li>flat roofs, and pitched roofs.</li></ul><p class="hd1" style="text-align: justify;">PIR term-AL construction</p><p style="text-align: justify;">The double-sided panel lining is made of KRAFT paper covered with aluminium (AL). The core of the panel is made of rigid polyisocyanurate foam (PIR) with very good insulating and fire-resistance properties Edges are milled for ease of installation and improvement in thermal insulation.</p><p class="hd1" style="text-align: justify;">Joint types</p><p style="text-align: justify;">Milling can be performed as follows:</p><table width="702"><tbody><tr style="text-align: center;"><td><strong>FIT</strong></td><td><strong>LAP</strong></td><td><strong>TAG</strong></td></tr><tr style="text-align: center;"><td>Straight edges</td><td>Overlap edges</td><td>Tounge and Groove</td></tr><tr style="text-align: center;"><td><img src="/images/products/pir/pir_0_fit.jpg" width="234" /></td><td><img src="/images/products/pir/pir_0_lap.jpg" width="234" /></td><td><img src="/images/products/pir/pir_0_tag.jpg" width="234" /></td></tr></tbody></table><p class="hd1" style="text-align: justify;">Technical data</p><table width="702"><tbody><tr style="text-align: center;"><td colspan="2">Parameter</td><td colspan="12">Value</td></tr><tr><td style="text-align: left;">Apparent density of core</td><td style="text-align: center;">kg/m<sup>3</sup></td><td colspan="12" style="text-align: center;">30 (<sup>+6</sup>/<sub>-2</sub>)</td></tr><tr><td style="text-align: left;">Declared heat conductivity coefficient &lambda;<sub>D</sub></td><td style="text-align: center;"><sup>W</sup>/<sub>m*K</sub></td><td colspan="12" style="text-align: center;">0.022</td></tr><tr><td style="text-align: left;">Panel thickness</td><td style="text-align: center;">mm</td><td style="text-align: center;">20</td><td style="text-align: center;">40</td><td style="text-align: center;">50</td><td style="text-align: center;">60</td><td style="text-align: center;">80</td><td style="text-align: center;">100</td><td style="text-align: center;">120</td><td style="text-align: center;">150</td><td style="text-align: center;">180</td><td style="text-align: center;">200</td><td style="text-align: center;">220</td><td style="text-align: center;">250</td></tr><tr><td style="text-align: left;">Thermal resistance R<sub>D</sub></td><td style="text-align: center;">m<sup>2</sup>*K/<sub>W</sub></td><td style="text-align: center;">0.90</td><td style="text-align: center;">1.80</td><td style="text-align: center;">2.25</td><td style="text-align: center;">2.70</td><td style="text-align: center;">3.60</td><td style="text-align: center;">4.50</td><td style="text-align: center;">5.45</td><td style="text-align: center;">6.80</td><td style="text-align: center;">8.15</td><td style="text-align: center;">9.05</td><td style="text-align: center;">10.00</td><td style="text-align: center;">11.35</td></tr><tr><td style="text-align: left;">Heat transfer coefficient U</td><td style="text-align: center;">W/m<sup>2</sup>*K</td><td style="text-align: center;">1.10</td><td style="text-align: center;">0.55</td><td style="text-align: center;">0.44</td><td style="text-align: center;">0.37</td><td style="text-align: center;">0.28</td><td style="text-align: center;">0.22</td><td style="text-align: center;">0.18</td><td style="text-align: center;">0.15</td><td style="text-align: center;">0.12</td><td style="text-align: center;">0.11</td><td style="text-align: center;">0.10</td><td style="text-align: center;">0.09</td></tr><tr><td colspan="2" style="text-align: left;">Fire reaction classification</td><td colspan="12" style="text-align: center;">E</td></tr><tr><td colspan="2" style="text-align: left;">Compressive strength</td><td colspan="12" style="text-align: center;">&ge; 120 kPa</td></tr></tbody></table>
10106 <p style="text-align: justify;"><strong>Polyisocyanurate panels</strong> are used as a component of thermal insulation systems. They provide efficient thermal insulation as compared to other construction materials such as mineral wool or foamed polystyrene. They allow for cost-effective, long-lasting, and safe use of a house or an apartment.</p><p style="text-align: justify;"><strong>Polyisocyanurate panels </strong>are used to insulate:</p><ul style="text-align: justify;"><li>foundations;</li><li>walls;</li><li>exterior walls;</li><li>ceilings;</li><li>terraces and balconies;</li><li>flat roofs, and pitched roofs.</li></ul><p class="hd1" style="text-align: justify;">PIR term-BT construction</p><p style="text-align: justify;">Panel is covered with with bitumen lining (BT). The core of the panel is made of rigid polyisocyanurate foam (PIR) with very good insulating and fire-resistance properties.</p><p class="hd1" style="text-align: justify;">Joint types</p><p style="text-align: justify;">Milling can be performed as follows:</p><table width="702"><tbody><tr style="text-align: center;"><td><strong>FIT</strong></td><td><strong>LAP</strong></td><td><strong>TAG</strong></td></tr><tr style="text-align: center;"><td>Straight edges</td><td>Overlap edges</td><td>Tounge and Groove</td></tr><tr style="text-align: center;"><td><img src="/images/products/pir/pir_0_fit.jpg" width="234" /></td><td><img src="/images/products/pir/pir_0_lap.jpg" width="234" /></td><td><img src="/images/products/pir/pir_0_tag.jpg" width="234" /></td></tr></tbody></table><p class="hd1" style="text-align: justify;">Technical data</p><table width="702"><tbody><tr style="text-align: center;"><td colspan="2">Parameter</td><td colspan="12">Value</td></tr><tr><td style="text-align: left;">Apparent density of core</td><td style="text-align: center;">kg/m<sup>3</sup></td><td colspan="12" style="text-align: center;">30 (<sup>+6</sup>/<sub>-2</sub>)</td></tr><tr><td style="text-align: left;">Panel thickness</td><td style="text-align: center;">mm</td><td style="text-align: center;">20</td><td style="text-align: center;">40</td><td style="text-align: center;">50</td><td style="text-align: center;">60</td><td style="text-align: center;">80</td><td style="text-align: center;">100</td><td style="text-align: center;">120</td><td style="text-align: center;">150</td><td style="text-align: center;">180</td><td style="text-align: center;">200</td><td style="text-align: center;">220</td><td style="text-align: center;">250</td></tr><tr><td style="text-align: left;">Declared heat conductivity coefficient &lambda;<sub>D</sub></td><td style="text-align: center;"><sup>W</sup>/<sub>m*K</sub></td><td colspan="4" style="text-align: center;">0.026</td><td colspan="2" style="text-align: center;">0.025</td><td colspan="6" style="text-align: center;">0.024</td></tr><tr><td style="text-align: left;">Thermal resistance R<sub>D</sub></td><td style="text-align: center;">m<sup>2</sup>*K/<sub>W</sub></td><td style="text-align: center;">0.75</td><td style="text-align: center;">1.50</td><td style="text-align: center;">1.90</td><td style="text-align: center;">2.30</td><td style="text-align: center;">3.20</td><td style="text-align: center;">4.00</td><td style="text-align: center;">5.00</td><td style="text-align: center;">6.25</td><td style="text-align: center;">7.50</td><td style="text-align: center;">8.30</td><td style="text-align: center;">9.15</td><td style="text-align: center;">10.40</td></tr><tr><td style="text-align: left;">Heat transfer coefficient U</td><td style="text-align: center;">W/m<sup>2</sup>*K</td><td style="text-align: center;">1.30</td><td style="text-align: center;">0.65</td><td style="text-align: center;">0.52</td><td style="text-align: center;">0.43</td><td style="text-align: center;">0.31</td><td style="text-align: center;">0.25</td><td style="text-align: center;">0.20</td><td style="text-align: center;">0.16</td><td style="text-align: center;">0.13</td><td style="text-align: center;">0.12</td><td style="text-align: center;">0.11</td><td style="text-align: center;">0.10</td></tr><tr><td colspan="2" style="text-align: left;">Fire reaction classification</td><td colspan="12" style="text-align: center;">F</td></tr><tr><td colspan="2" style="text-align: left;">Compressive strength</td><td colspan="12" style="text-align: center;">&ge; 120 kPa</td></tr></tbody></table>
10107 <p style="text-align: justify;"><strong>Polyisocyanurate panels</strong> are used as a component of thermal insulation systems. They provide efficient thermal insulation as compared to other construction materials such as mineral wool or foamed polystyrene. They allow for cost-effective, long-lasting, and safe use of a house or an apartment.</p><p style="text-align: justify;"><strong>Polyisocyanurate panels </strong>are used to insulate:</p><ul style="text-align: justify;"><li>foundations;</li><li>walls;</li><li>exterior walls;</li><li>ceilings;</li><li>terraces and balconies;</li><li>flat roofs, and pitched roofs.</li></ul><p class="hd1" style="text-align: justify;">PIR term-WS construction</p><p style="text-align: justify;">The double-sided panel lining is made of fiberglass. The core of the panel is made of rigid polyisocyanurate foam (PIR) with very good insulating and fire-resistance properties.</p><p class="hd1" style="text-align: justify;">Joint types</p><p style="text-align: justify;">Milling can be performed as follows:</p><table width="702"><tbody><tr style="text-align: center;"><td><strong>FIT</strong></td><td><strong>LAP</strong></td><td><strong>TAG</strong></td></tr><tr style="text-align: center;"><td>Straight edges</td><td>Overlap edges</td><td>Tounge and Groove</td></tr><tr style="text-align: center;"><td><img src="/images/products/pir/pir_0_fit.jpg" width="234" /></td><td><img src="/images/products/pir/pir_0_lap.jpg" width="234" /></td><td><img src="/images/products/pir/pir_0_tag.jpg" width="234" /></td></tr></tbody></table><p class="hd1" style="text-align: justify;">Technical data</p><table width="702"><tbody><tr style="text-align: center;"><td colspan="2">Parameter</td><td colspan="12">Value</td></tr><tr><td style="text-align: left;">Apparent density of core</td><td style="text-align: center;">kg/m<sup>3</sup></td><td colspan="12" style="text-align: center;">30 (<sup>+6</sup>/<sub>-2</sub>)</td></tr><tr><td style="text-align: left;">Panel thickness</td><td style="text-align: center;">mm</td><td style="text-align: center;">20</td><td style="text-align: center;">40</td><td style="text-align: center;">50</td><td style="text-align: center;">60</td><td style="text-align: center;">80</td><td style="text-align: center;">100</td><td style="text-align: center;">120</td><td style="text-align: center;">150</td><td style="text-align: center;">180</td><td style="text-align: center;">200</td><td style="text-align: center;">220</td><td style="text-align: center;">250</td></tr><tr><td style="text-align: left;">Declared heat conductivity coefficient &lambda;<sub>D</sub></td><td style="text-align: center;"><sup>W</sup>/<sub>m*K</sub></td><td colspan="4" style="text-align: center;">0.026</td><td colspan="2" style="text-align: center;">0.025</td><td colspan="6" style="text-align: center;">0.024</td></tr><tr><td style="text-align: left;">Thermal resistance R<sub>D</sub></td><td style="text-align: center;">m<sup>2</sup>*K/<sub>W</sub></td><td style="text-align: center;">0.75</td><td style="text-align: center;">1.50</td><td style="text-align: center;">1.90</td><td style="text-align: center;">2.30</td><td style="text-align: center;">3.20</td><td style="text-align: center;">4.00</td><td style="text-align: center;">5.00</td><td style="text-align: center;">6.25</td><td style="text-align: center;">7.50</td><td style="text-align: center;">8.30</td><td style="text-align: center;">9.15</td><td style="text-align: center;">10.40</td></tr><tr><td style="text-align: left;">Heat transfer coefficient U</td><td style="text-align: center;">W/m<sup>2</sup>*K</td><td style="text-align: center;">1.30</td><td style="text-align: center;">0.65</td><td style="text-align: center;">0.52</td><td style="text-align: center;">0.43</td><td style="text-align: center;">0.31</td><td style="text-align: center;">0.25</td><td style="text-align: center;">0.20</td><td style="text-align: center;">0.16</td><td style="text-align: center;">0.13</td><td style="text-align: center;">0.12</td><td style="text-align: center;">0.11</td><td style="text-align: center;">0.10</td></tr><tr><td colspan="2" style="text-align: left;">Fire reaction classification</td><td colspan="12" style="text-align: center;">E</td></tr><tr><td colspan="2" style="text-align: left;">Compressive strength</td><td colspan="12" style="text-align: center;">&ge; 120 kPa</td></tr></tbody></table>
10162 <table><tbody><tr><td colspan="2" rowspan="1" style="text-align: center; width: 430px;"><strong>Tekniska egenskaper</strong></td></tr><tr><td style="text-align: center; width: 215px;">Brandklass<br />(Euroklass)</td><td style="text-align: center; width: 215px;">brandsäker<br />A1</td></tr><tr><td style="text-align: center;">Värmekonduktivitet <strong>λ<sub>D</sub></strong></td><td style="text-align: center;">0.037 <sup>W</sup>/<sub>mK</sub></td></tr><tr><td style="text-align: center;">Längd</td><td style="text-align: center;">1000</td></tr><tr><td style="text-align: center;">Bredd</td><td style="text-align: center;">600</td></tr></tbody></table><table><tbody><tr><td colspan="4" rowspan="1" style="text-align: center; width: 400px;"><strong>Produktsortiment</strong></td></tr><tr><td style="text-align: center; width: 90px;">Tjocklek<br /><i>mm</i></td><td style="text-align: center; width: 130px;">Termisk resistans<br /><i><sup>m<sup>2</sup>K</sup>/<sub>W</sub></i></td><td style="text-align: center; width: 90px;">m<sup>2</sup> per<br />Paket</td><td style="text-align: center; width: 90px;">m<sup>2</sup> per<br />Pall</td></tr><tr><td style="text-align: center;">20</td><td style="text-align: center;"><strong>0.50</strong></td><td style="text-align: center;">4.80</td><td style="text-align: center;">134.40</td></tr><tr><td style="text-align: center;">30</td><td style="text-align: center;"><strong>0.80</strong></td><td style="text-align: center;">4.80</td><td style="text-align: center;">96.00</td></tr><tr><td style="text-align: center;">40</td><td style="text-align: center;"><strong>1.05</strong></td><td style="text-align: center;">3.60</td><td style="text-align: center;">72.00</td></tr><tr><td style="text-align: center;">50</td><td style="text-align: center;"><strong>1.35</strong></td><td style="text-align: center;">2.40</td><td style="text-align: center;">57.60</td></tr></tbody></table>